Setting of Wall or Slab
Where do I find the setting to specify the entered structural component as a "wall" or "slab"?
Answer:
You can find this setting in the "General Data" of the model.
Here you can distinguish between the model types "3D", "2D - XY", "2D - XZ", and "2D - XY".
If you want to enter a slab as a 2D model and the axial forces within the slab should not be taken into account, set the model type to "2D - XY". If you want to enter a wall, set "2D - XZ".
Further information on this can be found in the RFEM manual, Chapter 12.2.1 General - Type of Model.
Do you have any questions?
In this article, the calculation of a timber panel wall with the beam panel thickness type is compared with a manual calculation.
Using the Timber Design add-on, timber column design is possible according to the 2018 NDS standard ASD method. Accurately calculating timber member compressive capacity and adjustment factors is important for safety considerations and design. The following article will verify the maximum critical buckling strength calculated by the Timber Design add-on using step-by-step analytical equations as per the NDS 2018 standard including the compressive adjustment factors, adjusted compressive design value, and final design ratio.
The three types of moment frames (Ordinary, Intermediate, Special) are available in the Steel Design add-on of RFEM 6. The seismic design result according to AISC 341-22 is categorized into two sections: member requirements and connection requirements.
The fatigue design according to EN 1992-1-1 must be performed for the structural components subjected to large stress ranges and/or many load changes. In this case, the design checks for the concrete and the reinforcement are performed separately. There are two alternative design methods available.
In the Concrete Design add-on, you have the option to define an existing vertically oriented punching shear reinforcement. This is then taken into account in the punching shear design.
In RFEM, the oriented strand board (OSB) material is available for the USA and Canada. The material parameters are taken from the "Panel Design Specification manual".
In the ultimate configuration of the steel joint design, you have the option to modify the limit plastic strain for welds.
The "Base Plate" component allows you to design base plate connections with cast-in anchors. In this case, plates, welds, anchorages, and steel-concrete interaction are analyzed.